Archive:Noctar: Difference between revisions
Jump to navigation
Jump to search
SimonRichter (talk | contribs) m (Categorize) |
SimonRichter (talk | contribs) No edit summary |
||
Line 1: | Line 1: | ||
== Organizational == | == Organizational == | ||
Contact [[SimonRichter|Simon]] if you want to use the system. You should have knowledge of radio frequency technology and regulations. There will be a test. | Contact [[User:SimonRichter|Simon]] if you want to use the system. You should have knowledge of radio frequency technology and regulations. There will be a test. | ||
== Technical == | == Technical == |
Revision as of 16:01, 17 February 2014
Organizational
Contact Simon if you want to use the system. You should have knowledge of radio frequency technology and regulations. There will be a test.
Technical
- Direct Quadrature Receiver/Transmitter
- Separate LOs for receive and transmit paths
- 55 MHz IF lowpass filter
- 2x125 MSa/s 12 bit ADCs
- Altera EP4CGX22C FPGA with DSP core
- 2x250 MSa/s 16 bit DACs
Projects
Rewriting the FPGA firmware
The factory firmware has several drawbacks that make it difficult to use the system easily:
- Decimation is done in 5 stages, each halving the sample rate. This leads to an awful lot of digital filter noise, and decimation 32 is not really sufficient for most applications.
* New design using a 2x16 multiplier FIR filter with symmetry handling and accumulator (i.e. 31 coefficients in a symmetric lowpass filter design without decimation) * Additional fixed IIR filters implementing high decimation factors
- Table based NCO. This takes up lots of FPGA space, and has limited accuracy.