Date | User | Notes |
---|---|---|
Nov 2nd | Tiefpunkt | Laser out of order, not to be used. Mirror 2 was loose again, after retightning not really alligned. Before realigning, mirrors should be switched for the now ones, which should fit the mirror mounts much better. Peter tried some calibration, but one of the screws of mirror 2 was too tight and the plastic handle on it broke. Reattached with superglue. |
Oct 19th | Siedi | Replaced SSR for the exhaust air. The switch is working again. |
Oct 18th | Eax | Laser cutter is operable. Air compressor was removed from the frame. Water protect issue not reproducible. 75mm lens assembled. 50mm lens is missing. |
Oct 14th | Eax | Laser is calibrated. BUT: Air compressor not working AND "Water protect" triggered every now and then. |
Oct 7th | Tiefpunkt (talk) | SSR of exhaust broken, won't turn exhaust off. Severin will get a replacement part. |
Oct 5th | Tiefpunkt (talk) | Laser out of alignment again after longer laser job. Mirror assembly no. 2 gets warm, and loosens screw again. Repeated hot-cold cycles will make it the screw loose and the mirror wiggle out of position. Laser deemed not usable until realignment incl. mirror no. 1 as well. We'll look for a replacement mirror as well. |
Sep 30th | Tiefpunkt (talk) | Laser out of alignment again. Mirror No. 2 loose inside its holder. Mirror assembly screwed out of holder, mirror cleaned, and put back into assembly. Assembly holds 25mm mirrors, but the mirror seems slightly bigger, thus does not sit flush in the assembly, just jammed in there as tight as possible. Mirror put back in, and mirror no. 2 realigned, works fairly well for now. |
Sep 28th | Tiefpunkt (talk) | Laser aligned by Peter |