LaserCutter/Log: Difference between revisions

From The Munich Maker Lab's Wiki
Jump to navigation Jump to search
(maintenance)
m (Added clearer status icon)
Line 1: Line 1:
== 2017 ==
== 2017 ==
{| class="wikitable"
{| class="wikitable"
! Date !! User !! Notes  
! Date !! User !! State !! Notes  
|-
|-
| Dec 1st
| Dec 1st
| [[User:Eax|Eax]]  
| [[User:Eax|Eax]]  
| 🛑
| Laser out of order, not to be used. Mirror cover on the laser tube itself was loose, because presumably s.o. tried to attach a too tight pilot laser holding assembly. Fixed the mirror cover to its place by using glue.
| Laser out of order, not to be used. Mirror cover on the laser tube itself was loose, because presumably s.o. tried to attach a too tight pilot laser holding assembly. Fixed the mirror cover to its place by using glue.
|-
|-
| Nov 29
| Nov 29
| [[User:Eax|Eax]]  
| [[User:Eax|Eax]]  
| 🛑
| Laser out of order, not to be used. Replaced all three mirrors with the new batch of mirrors. Determined that the position of the 1st mirror is not aligned with the linear axis of the 2nd mirror (X axis movement). This leads to a drift of the spot on the 2nd mirror. The position of the first mirror needs correction. For this a pilot laser (red visible) would be ideal.
| Laser out of order, not to be used. Replaced all three mirrors with the new batch of mirrors. Determined that the position of the 1st mirror is not aligned with the linear axis of the 2nd mirror (X axis movement). This leads to a drift of the spot on the 2nd mirror. The position of the first mirror needs correction. For this a pilot laser (red visible) would be ideal.
|-
|-
| Nov 2nd
| Nov 2nd
| [[User:Tiefpunkt|Tiefpunkt]]  
| [[User:Tiefpunkt|Tiefpunkt]]  
| 🛑
| Laser out of order, not to be used. Mirror 2 was loose again, after retightning not really alligned. Before realigning, mirrors should be switched for the now ones, which should fit the mirror mounts much better. Peter tried some calibration, but one of the screws of mirror 2 was too tight and the plastic handle on it broke. Reattached with superglue.  
| Laser out of order, not to be used. Mirror 2 was loose again, after retightning not really alligned. Before realigning, mirrors should be switched for the now ones, which should fit the mirror mounts much better. Peter tried some calibration, but one of the screws of mirror 2 was too tight and the plastic handle on it broke. Reattached with superglue.  
|-
|-
| Oct 19th
| Oct 19th
| [[User:Siedi|Siedi]]  
| [[User:Siedi|Siedi]]  
| ✅
| Replaced SSR for the exhaust air. The switch is working again.
| Replaced SSR for the exhaust air. The switch is working again.
|-
|-
| Oct 18th
| Oct 18th
| [[User:Eax|Eax]]  
| [[User:Eax|Eax]]  
| ✅
| Laser cutter is operable. Air compressor was removed from the frame. Water protect issue not reproducible. 75mm lens assembled. 50mm lens is missing.
| Laser cutter is operable. Air compressor was removed from the frame. Water protect issue not reproducible. 75mm lens assembled. 50mm lens is missing.
|-
|-
| Oct 14th
| Oct 14th
| [[User:Eax|Eax]]  
| [[User:Eax|Eax]]  
| ✅
| Laser is calibrated. BUT: Air compressor not working AND "Water protect" triggered every now and then.
| Laser is calibrated. BUT: Air compressor not working AND "Water protect" triggered every now and then.
|-
|-
| Oct 7th
| Oct 7th
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| ⚠️
| SSR of exhaust broken, won't turn exhaust off. Severin will get a replacement part.  
| SSR of exhaust broken, won't turn exhaust off. Severin will get a replacement part.  
|-
|-
| Oct 5th
| Oct 5th
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| 🛑
| Laser out of alignment again after longer laser job. Mirror assembly no. 2 gets warm, and loosens screw again. Repeated hot-cold cycles will make it the screw loose and the mirror wiggle out of position. Laser deemed not usable until realignment incl. mirror no. 1 as well. We'll look for a replacement mirror as well.
| Laser out of alignment again after longer laser job. Mirror assembly no. 2 gets warm, and loosens screw again. Repeated hot-cold cycles will make it the screw loose and the mirror wiggle out of position. Laser deemed not usable until realignment incl. mirror no. 1 as well. We'll look for a replacement mirror as well.
|-
|-
| Sep 30th
| Sep 30th
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| ✅
| Laser out of alignment again. Mirror No. 2 loose inside its holder. Mirror assembly screwed out of holder, mirror cleaned, and put back into assembly. Assembly holds 25mm mirrors, but the mirror seems slightly bigger, thus does not sit flush in the assembly, just jammed in there as tight as possible. Mirror put back in, and mirror no. 2 realigned, works fairly well for now.
| Laser out of alignment again. Mirror No. 2 loose inside its holder. Mirror assembly screwed out of holder, mirror cleaned, and put back into assembly. Assembly holds 25mm mirrors, but the mirror seems slightly bigger, thus does not sit flush in the assembly, just jammed in there as tight as possible. Mirror put back in, and mirror no. 2 realigned, works fairly well for now.
|-
|-
| Sep 28th
| Sep 28th
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| [[User:Tiefpunkt|Tiefpunkt]] ([[User talk:Tiefpunkt|talk]])
| ✅
| Laser aligned by Peter
| Laser aligned by Peter
|}
|}

Revision as of 13:10, 2 December 2017

2017

Date User State Notes
Dec 1st Eax 🛑 Laser out of order, not to be used. Mirror cover on the laser tube itself was loose, because presumably s.o. tried to attach a too tight pilot laser holding assembly. Fixed the mirror cover to its place by using glue.
Nov 29 Eax 🛑 Laser out of order, not to be used. Replaced all three mirrors with the new batch of mirrors. Determined that the position of the 1st mirror is not aligned with the linear axis of the 2nd mirror (X axis movement). This leads to a drift of the spot on the 2nd mirror. The position of the first mirror needs correction. For this a pilot laser (red visible) would be ideal.
Nov 2nd Tiefpunkt 🛑 Laser out of order, not to be used. Mirror 2 was loose again, after retightning not really alligned. Before realigning, mirrors should be switched for the now ones, which should fit the mirror mounts much better. Peter tried some calibration, but one of the screws of mirror 2 was too tight and the plastic handle on it broke. Reattached with superglue.
Oct 19th Siedi Replaced SSR for the exhaust air. The switch is working again.
Oct 18th Eax Laser cutter is operable. Air compressor was removed from the frame. Water protect issue not reproducible. 75mm lens assembled. 50mm lens is missing.
Oct 14th Eax Laser is calibrated. BUT: Air compressor not working AND "Water protect" triggered every now and then.
Oct 7th Tiefpunkt (talk) ⚠️ SSR of exhaust broken, won't turn exhaust off. Severin will get a replacement part.
Oct 5th Tiefpunkt (talk) 🛑 Laser out of alignment again after longer laser job. Mirror assembly no. 2 gets warm, and loosens screw again. Repeated hot-cold cycles will make it the screw loose and the mirror wiggle out of position. Laser deemed not usable until realignment incl. mirror no. 1 as well. We'll look for a replacement mirror as well.
Sep 30th Tiefpunkt (talk) Laser out of alignment again. Mirror No. 2 loose inside its holder. Mirror assembly screwed out of holder, mirror cleaned, and put back into assembly. Assembly holds 25mm mirrors, but the mirror seems slightly bigger, thus does not sit flush in the assembly, just jammed in there as tight as possible. Mirror put back in, and mirror no. 2 realigned, works fairly well for now.
Sep 28th Tiefpunkt (talk) Laser aligned by Peter