| Oct 19th
| [[User:Siedi|Siedi]]
| Replaced SSR for the exhaust air. The switch is working again.
|-
|-
| Oct 18th
| Oct 18th

Revision as of 12:59, 25 October 2017

2017

Date User Notes
Oct 19th Siedi Replaced SSR for the exhaust air. The switch is working again.
Oct 18th Eax Laser cutter is operable. Air compressor was removed from the frame. Water protect issue not reproducible. 75mm lens assembled. 50mm lens is missing.
Oct 14th Eax Laser is calibrated. BUT: Air compressor not working AND "Water protect" triggered every now and then.
Oct 7th Tiefpunkt (talk) SSR of exhaust broken, won't turn exhaust off. Severin will get a replacement part.
Oct 5th Tiefpunkt (talk) Laser out of alignment again after longer laser job. Mirror assembly no. 2 gets warm, and loosens screw again. Repeated hot-cold cycles will make it the screw loose and the mirror wiggle out of position. Laser deemed not usable until realignment incl. mirror no. 1 as well. We'll look for a replacement mirror as well.
Sep 30th Tiefpunkt (talk) Laser out of alignment again. Mirror No. 2 loose inside its holder. Mirror assembly screwed out of holder, mirror cleaned, and put back into assembly. Assembly holds 25mm mirrors, but the mirror seems slightly bigger, thus does not sit flush in the assembly, just jammed in there as tight as possible. Mirror put back in, and mirror no. 2 realigned, works fairly well for now.
Sep 28th Tiefpunkt (talk) Laser aligned by Peter